Support

Entree Spa Gen II
Image

ENTRE SPA GEN II

ARCHITECTURAL SPECIFICATIONS & ROUGH-IN INFORMATION
Image

STANDARD LENGTH MODELS

Exterior Dimensions

Width
All models below (Door Closed)
36"
Width
All models below (Door Opened)
34.25"
Length
MB-59-AV —Alcove Placement
36"
Length
MB-68-AVH —Head End Corner Placement
62.5"
Length
MB-68-AVF —Foot End Corner Placement
62.5"
Length
MB-68-AV —Standard Wall Placement
65.5"
Length
All models above to the top of controls
46.5"

Interior Dimensions

Length-Straight
45"
Length-Diagonal
47"
Seat Depth
22" at Widest Point"
Seat Area Width (w/ Door Closed)
25"
Seat Height
21.5"

Specifications

Back Flow Prevention:
Double check valves for shower wand complies with CSA B64.7, UPC, Certified to NSF/ANSI 372, ASSE 1035—“Laboratory Faucet Vacuum Breakers”. Fill: 1.5” A gap above rim complies with National Plumbing Standards. (See plumbing standards below.) Note: The factory provided backflow prevention is the most widely accepted. Local codes may require changes. The local plumbing contractor is responsible for any changes.
BathAire(SM) Outlets:
4 with 12 ports each for a total of 48 warm air massage outlets.
Door Seal:
Seal certified by Warnock Hersey to the ASME A112.19.15-2005, CSA B45.0-02 (R2008) and ANSI Z124.1.2 (2008) standards to ensure long lasting durability for bathtubs with pressure sealed doors. Highly resistant to oils, detergents and all water conditions.
Electrical:
Factory provided on board installed dead front GFCI: UL/CSA approved.
Installation Time:
1 hour (when water and electrical supplies meet the provided rough-ins.) Inspection and Adjustments: 1/2 hour
Motor Specs:

Door motor: 115 V., 4.2 Amp, 1/3 H.P.

BathAire(SM) Motor: 120 V, 11 Amp, 1.3 H.P. Variable speed with built-in 600 watt heating element for maximum comfort and control.

Room Size:
5' 11" wide x 9' 7 ½” long minimum recommended. Can fit in smaller room--call MasterCare with dimensions.
Switches:
Membrane and Pneumatic.
Thermometer: Tub
Solar / Digital temperature measurements.
Door/Entry:
Door full length of tub with tub seat extending over the floor surface.
Tub Fill/Shower:
Built-in thermostatic mixing valve certified to ASSE 1016-2005, ASME A112.18.1-2005, CSA B125 and UPC listed.
Tub Fill / Shower shut off:
Valves certified ASSE and UPC listed with ceramic disc controls.
Tub Shell:
Sanitary gel-coated FRP (Fiberglass Reinforced Polymer).
Tub Water Use:
45 gallons minimum with normal displacement 4 inches below overflow escutcheon.
Waste:
2" PVC schedule 40 pipe. DO NOT Hard-Plumb for ease of accessibility for servicing.
Water Connection:
¾” SS braided flex hose with female pipe thread connections.
Water Supply:
¾” hot and cold with shut-offs. Hot and cold water pressure 45-90 psi. Hot water temperature to be 120º F and cold water 59º F.
Weight
500 lbs
Fill Rate:
In excess of 17 GPM provided that the water lines are ¾”, water pressure is at least 60 psi and the hot water is 120º F. Community and/or other environmental factors may affect the fill rate.
Establishment Registration:
3003336913

EXTENDED LENGTH MODELS

Exterior Dimensions

Width
All models below (Door Closed)
36"
Width
All models below (Door Opened)
34.25"
Length
MB-59-AV —Alcove Placement

65.5"

Length
MB-68-AVH —Head End Corner Placement

68.5"

Length
MB-68-AVF —Foot End Corner Placement

68.5"

Length
MB-68-AV —Standard Wall Placement

71.5"

Length
All models above to the top of controls
46.5"

Interior Dimensions

Length-Straight

51"

Length-Diagonal
52"
Seat Depth
22" at Widest Point"
Seat Area Width (w/ Door Closed)
25"
Seat Height
21.5"

Specifications

Back Flow Prevention:
Double check valves for shower wand complies with CSA B64.7, UPC, Certified to NSF/ANSI 372, ASSE 1035—“Laboratory Faucet Vacuum Breakers”. Fill: 1.5” A gap above rim complies with National Plumbing Standards. (See plumbing standards below.) Note: The factory provided backflow prevention is the most widely accepted. Local codes may require changes. The local plumbing contractor is responsible for any changes.
BathAire(SM) Outlets:
4 with 12 ports each for a total of 48 warm air massage outlets.
Door Seal:
Seal certified by Warnock Hersey to the ASME A112.19.15-2005, CSA B45.0-02 (R2008) and ANSI Z124.1.2 (2008) standards to ensure long lasting durability for bathtubs with pressure sealed doors. Highly resistant to oils, detergents and all water conditions.
Electrical:
Factory provided on board installed dead front GFCI: UL/CSA approved.
Installation Time:
1 hour (when water and electrical supplies meet the provided rough-ins.) Inspection and Adjustments: 1/2 hour
Motor Specs:

Door motor: 115 V., 4.2 Amp, 1/3 H.P.

BathAire(SM) Motor: 120 V, 11 Amp, 1.3 H.P. Variable speed with built-in 600 watt heating element for maximum comfort and control.

Room Size:
6' 5" wide x 10' 1 ½” long minimum recommended. Can fit in smaller room--call MasterCare with dimensions.
Switches:
Membrane and Pneumatic.
Thermometer: Tub
Solar / Digital temperature measurements.
Door/Entry:
Door full length of tub with tub seat extending over the floor surface.
Tub Fill/Shower:
Built-in thermostatic mixing valve certified to ASSE 1016-2005, ASME A112.18.1-2005, CSA B125 and UPC listed.
Tub Fill / Shower shut off:
Valves certified ASSE and UPC listed with ceramic disc controls.
Tub Shell:
Sanitary gel-coated FRP (Fiberglass Reinforced Polymer).
Tub Water Use:
55 gallons minimum with normal displacement 4 inches below overflow escutcheon.
Waste:
2" PVC schedule 40 pipe. DO NOT Hard-Plumb for ease of accessibility for servicing.
Water Connection:
¾” SS braided flex hose with female pipe thread connections.
Water Supply:
¾” hot and cold with shut-offs. Hot and cold water pressure 45-90 psi. Hot water temperature to be 120º F and cold water 59º F.
Weight
500 lbs
Fill Rate:
In excess of 17 GPM provided that the water lines are ¾”, water pressure is at least 60 psi and the hot water is 120º F. Community and/or other environmental factors may affect the fill rate.
Establishment Registration:
3003336913