Entree Spa GII Specifications

ARCHITECTURAL SPECIFICATIONS & ROUGH-IN INFORMATION


STANDARD LENGTH MODELS

Exterior Dimensions
Width All models below (Door Closed) 36"
Width All models below (Door Opened) 34.25"
Length MB-59-AV —Alcove Placement 59.5"
Length MB-68-AVH —Head End Corner Placement 62.5"
Length MB-68-AVF —Foot End Corner Placement 62.5"
Length MB-68-AV —Standard Wall Placement 65.5"
Height All models above to the top of controls 46.5"
Interior Dimensions
Length-Straight 45"
Length-Diagonal 47"
Seat Depth 22" at Widest Point
Seat Area Width (w/ Door Closed) 25"
Seat Height 21.5"
Specifications
Back Flow Prevention: Double check valves for shower wand complies with CSA B64.7, UPC, Certified to NSF/ANSI 372, ASSE 1035—“Laboratory Faucet Vacuum Breakers”. Fill: 1.5” A gap above rim complies with National Plumbing Standards. (See plumbing standards below.) Note: The factory provided backflow prevention is the most widely accepted. Local codes may require changes. The local plumbing contractor is responsible for any changes.
BathAire(SM) Outlets: 4 with 12 ports each for a total of 48 warm air massage outlets.
Door Seal: Seal certified by Warnock Hersey to the ASME A112.19.15-2005, CSA B45.0-02 (R2008) and ANSI Z124.1.2 (2008) standards to ensure long lasting durability for bathtubs with pressure sealed doors. Highly resistant to oils, detergents and all water conditions.
Electrical: Factory provided on board installed dead front GFCI: UL/CSA approved.
Installation Time: 1 hour (when water and electrical supplies meet the provided rough-ins.)
Inspection and Adjustments: 1/2 hour
Motor Specs: Door motor: 115 V., 4.2 Amp, 1/3 H.P.
BathAire(SM) Motor: 120 V, 11 Amp, 1.3 H.P. Variable speed with built-in 600 watt heating element for maximum comfort and control.
Room Size: 5' 11" wide x 9' 7 ½” long minimum recommended. Can fit in smaller room--call MasterCare with dimensions.
Electrical Standards: CAN/CSA C22.2 No. 218.2-93 (R2006) Hydromassage Bathtub Appliances.
UL 1795 Hydromassage Bathtubs, Issue: 2009/08/05 Ed: 4 Rev: 2010/03/23
Plumbing Standards: Warnock Hersey: CSA B45.5 (2008), ASME A112.19.15 (2005), CSA B45S1 (2004), ANSI Z124.1.2 (2005).
Switches: Membrane and Pneumatic.
Thermometer: Tub Solar / Digital temperature measurements.
Door/Entry: Door full length of tub with tub seat extending over the floor surface.
Tub Fill/Shower: Built-in thermostatic mixing valve certified to ASSE 1016-2005, ASME A112.18.1-2005, CSA B125 and UPC listed.
Tub Fill / Shower shut off: Valves certified ASSE and UPC listed with ceramic disc controls.
Tub Shell: Sanitary gel-coated FRP (Fiberglass Reinforced Polymer).
Tub Water Use: 45 gallons minimum with normal displacement 4 inches below overflow escutcheon.
Waste: 2" PVC schedule 40 pipe. DO NOT Hard-Plumb for ease of accessibility for servicing.
Water Connection: ¾” SS braided flex hose with female pipe thread connections.
Water Supply: ¾” hot and cold with shut-offs. Hot and cold water pressure 45-90 psi. Hot water temperature to be 120º F and cold water 59º F.
Weight: 500 lbs.
Fill Rate: In excess of 17 GPM provided that the water lines are ¾”, water pressure is at least 60 psi and the hot water is 120º F. Community and/or other environmental factors may affect the fill rate.
Establishment Registration: 3003336913

 

EXTENDED LENGTH MODELS

Exterior Dimensions
Width All models below (Door Closed) 36"
Width All models below (Door Opened) 34.25"
Length MB-59-AV —Alcove Placement 65.5"
Length MB-68-AVH —Head End Corner Placement 68.5"
Length MB-68-AVF —Foot End Corner Placement 68.5"
Length MB-68-AV —Standard Wall Placement 71.5"
Height All models above to the top of controls 46.5"
Interior Dimensions
Length-Straight 51"
Length-Diagonal 52"
Seat Depth 22" at Widest Point
Seat Area Width (w/ Door Closed) 25"
Seat Height 21.5"
Specifications
Back Flow Prevention: Double check valves for shower wand complies with CSA B64.7, UPC, Certified to NSF/ANSI 372, ASSE 1035—“Laboratory Faucet Vacuum Breakers”. Fill: 1.5” a gap above rim complies with National Plumbing Standards. (See plumbing standards below.) Note: The factory provided backflow prevention is the most widely accepted. Local codes may require changes. The local plumbing contractor is responsible for any changes.
BathAire(SM) Outlets: 4 with 12 ports each for a total of 48 warm air massage outlets.
Door Seal: Seal certified by Warnock Hersey to the ASME A112.19.15-2005, CSA B45.0-02 (R2008) and ANSI Z124.1.2 (2008) standards to ensure long lasting durability for bathtubs with pressure sealed doors. Highly resistant to oils, detergents and all water conditions.
Electrical: Factory provided on board installed dead front GFCI: UL/CSA approved.
Installation Time: 1 hour (when water and electrical supplies meet the provided rough-ins).
Inspection and Adjustments: 1/2 hour
Motor Specs: Door motor: 115 V, 4.2 Amp, 1/3 H.P.
BathAire(SM) Motor: 120 V., 11 Amp, 1.3 H.P. Variable speed with built-in 600 watt heating element for maximum comfort and control.
Room Size: 6’ 5" wide x 10’ 1½” long minimum recommended. Can fit in smaller room--call MasterCare with dimensions.
Electrical Standards: CAN/CSA C22.2 No. 218.2-93 (R2006) Hydromassage Bathtub Appliances.
UL 1795 Hydromassage Bathtubs, Issue: 2009/08/05 Ed: 4 Rev: 2010/03/23
Plumbing Standards: Warnock Hersey: CSA B45.5 (2008), ASME A112.19.15 (2005), CSA B45S1 (2004), ANSI Z124.1.2 (2005).
Switches: Membrane and Pneumatic.
Thermometer: Tub Solar / Digital temperature measurements.
Door/Entry: Door full length of tub with tub seat extending over the floor surface.
Tub Fill/Shower: Built-in thermostatic mixing valve certified to ASSE 1016-2005, ASME A112.18.1-2005, CSA B125 and UPC listed.
Tub Fill / Shower shut off: Valves certified ASSE and UPC listed with ceramic disc controls.
Tub Shell: Sanitary gel-coated FRP (Fiberglass Reinforced Polymer).
Tub Water Use: 55 gallons minimum with normal displacement 4 inches below overflow escutcheon.
Waste: 2" PVC schedule 40 pipe. DO NOT Hard-Plumb for ease of accessibility for servicing.
Water Connection: ¾” SS braided flex hose with female pipe thread connections.
Water Supply: ¾” hot and cold with shut-offs. Hot and cold water pressure 45-90 psi. Hot water temperature to be 120º F and cold water 59º F.
Weight: 500 lbs.
Fill Rate: In excess of 17 GPM provided that the water lines are ¾”, water pressure is at least 60 psi and the hot water is 120º F. Community and/or other environmental factors may affect the fill rate.
Establishment Registration: 3003336913